Controlled characteristics
The principal reliability characteristics are mean time to failure (MTTF) and mean time between failures (MTBF). Failure rate and failure intensity can be controlled by transition to reciprocal values. Mean time to recovery is also relevant for maintainable products.
How a test plan is defined
A plan is defined before testing. Its main inputs are the acceptance-to-rejection level ratio D, producer's risk α and consumer's risk β.
Practical constraints
- maximum allowable calendar duration;
- maximum accumulated test time;
- number of items under test and items tested simultaneously;
- permitted failures and recovery conditions.
In graphical form, acceptance and rejection boundaries are represented against accumulated test time and number of failures.
Test plan types
T/S — truncated sequential
Parameters A, B, R and Tmax. Provides high efficiency with a maximum accumulated test-time limit.
New1
Parameters A, B and R. Parameter B provides a gradually changing acceptance boundary; this type often gives the highest efficiency.
New2
A calculated new-type plan with A, B and R parameters for conditions requiring a different boundary geometry.
T/F — Time / Failure
A conventional plan with A and R parameters. It is simpler, but generally less accurate and less efficient than calculated alternatives.
Test efficiency
Efficiency is the saving in test volume while retaining the required accuracy and confidence. Volume is characterized by the expected accumulated test time to any decision T0 and the expected test time to an acceptance decision T0(+).
Optimal plans can reduce test volume by 5–40%, or about 20% on average, compared with a less suitable scheme.
Catalogue and New Plans
The printed catalogue has 11 parts and contains about 1,500 accurate plans for D values from 1.5 to 3.0 and combinations of α and β risks from 0.05 to 0.30.
The New Plans PC-program database contains more than 2,000 plans for 400 combinations of initial data. It supports plan selection and comparison, calculation of new plans, database management and standard-form printing. Version 1.0 was developed in 1998; this site preserves its methodological and historical information.
Standards and standardization
Optimal plan selection is a standardization task in reliability testing. The methods contributed to GOST 27.402‑95 “Dependability in Technics. Test plans for controlling the mean time to failure (between failures)” and to work within IEC/TC 56 “Dependability”.
Comparison of plan sources
| Characteristic | IEC 61124 | GOST 27.402‑95 | Catalogue | New Plans |
|---|---|---|---|---|
| Total number of plans | 18 | 61 | ≈1,500 | Unlimited; 2,000+ in database |
| Plan types | 2 | 4 | 4 | 4 |
| Truncation levels | 1 | 2 | 2 | Unlimited |
| Specific test conditions | Absent | Medium | High | Full selection for conditions |